Air Conditioned Server Rack Cabinets

DEFENDER™ server cabinets are an efficient, self-contained cooling system ideal for use in remote locations, wiring closets, office locations, and industrial environments that don’t have cooling infrastructure already in place.

DEFENDER™

DefenderBrand


Capable of providing up to 4 kW of cooling, these cabinets with NEMA rated air conditioners protect the delicate electronics inside from heat, dirt, moisture, and tampering. Simply put, these cabinets are a cost-effective alternative to installing a data center with a climate-controlled cooling system.

Features

DefenderBrand

Server Cabinet Features
  • Welded 12-gauge steel frame with 2000 lbs. [907 kg.] static load capacity
  • Fully gasketed locking front door with viewing window
  • Fully gasketed locking rear door
  • 19″ EIA Square hole rails can accept Rackstuds
  • Gland plate in top for cable entry/exit
  • Brushed grommet cable entry/exit in bottom
  • Compatible with GapFill™ airflow management accessories
  • Remote monitoring capability
AC Unit Features
  • Designed to mount on the side of the enclosure while maintaining NEMA 12, 3R, 4, or 4X integrity.
  • Digital temperature controller with alarm
  • 120V standard 230V Optional
  • Built-in condensate evaporator
  • Efficient, quiet, long lasting rotary compressor
  • Environment friendly HFC refrigerant
  • Easy pull-out filter
  • UL Listed
Specifications
  • Welded 12-gauge steel frame
  • Rails have square holes with EIA 310-D spacing
Paint / Finish
  • Color: Select from one of nine proprietary color options. Sample kits are available upon request.
  • Our products are finished in textured powder paint. Powder coating provides a durable high-quality finish.
Load Rating
  • Static Load Rating: 2000 lbs. [907 kg.]
  • A cabinet has a static load when:
    • It is in its final, permanent, fully secured location, and
    • Its load is uniformly applied to the two sets of rack-mounting rails
  • Never move a cabinet with its maximum static load applied.
Industry Standards
  • EIA 310-D

FAQ's

DefenderBrand

How to determine the size of AC unit (BTU’s) needed?

Follow these steps. Contact the factory for assistance if needed.

  • Take the nameplate power specified of each component (in WATTS) to be installed in the cabinet and add them up.
  • Reduce (derate) by 30%.
  • OPTIONAL – If more components will be added in the future add a 20% safety factor.
  • Multiply total WATTS by 3.41 to convert to BTU’s.

EXAMPLE
You have the following components: QTY 20 – 1U servers at 150 WATTS each. QTY 2 – 5U switches at 200 WATTS each.

3400 WATTS Total
Derate by 30% (3400 WATTS = 2380 WATTS)
Add 20% for future expansion (2380 x 20% = 2856 WATTS)
Multiply by 3.41 to get BTU’s (2856 x 3.41 = 9,738 BTU’s)
In this example a 12,000 BTU AC unit is recommended*

*Assumptions – Room size is larger than 12’ x 12’ x 12’.  Ambient temperature is 85 °F


How to manage the condensate?

The AC unit will not produce condensate if properly installed. These AC units utilize a closed loop system where moisture, if created, is evaporated inside the AC unit itself.

Because this is a closed loop system, there is no need to vent this system.


How does it ship?

The cabinet ships on a pallet. The AC unit ships securely inside of the cabinet. A loading dock is required for standard shipment. Special accommodations can be made for a lift gate or inside delivery.

Double check the overall dimensions of the cabinet to make sure the path from the delivery location to installation location is clear. Make sure it will fit under, and through (width wise), all doorways and/or in elevators.


How to install the AC unit on the cabinet?

The right side of the cabinet (left side mounting upon request) is pre-configured to accommodate the AC unit. Un-box the AC unit, apply the gasket material, and lift into place. Two people are required to lift the AC unit into place. All hardware is included. 

You may need to mount the AC unit AFTER you put the cabinet in the designated location.


What are the power requirements?

A dedicated circuit is required. 20 AMP is preferred, but 15 AMP may be sufficient based on the size of the AC unit. Consult a licensed electrician to determine if you have appropriate power running to the location where the cabinet will be installed.

The cabinet is set up to bring the power into the bottom of the cabinet as shown below:

<<INSERT IMAGE>>


How to get cables into the cabinet?

Communication cables should come through the top. The top of this cabinet allows terminated cables to drop in through the sliding top cover. Before starting to populate, be sure to check the service loop length is long enough.

Once closed, the compressible memory foam sheets, with a fire and chemical retardant impregnated throughout the
material, seals off the top to eliminate airflow leaks. Max opening is 15.25″ wide x 19.50″ deep.


Are modifications possible?

Yes, we can accommodate most requests. Please contact an EMCOR sales representative with the details.


Pre-configured Cabinets

DefenderBrand

Pre-configured Server Cabinets

It’s about saving time without compromise —
We have selected the most common sizes and paired them with the most common accessories to provide the ultimate datacom solution – FAST!
Call us and we can get your order processed immediately. 507-287-3535

defenderfull

Full Rack – Self-contained Cooling Server Cabinet Systems
Includes: Frame, 2 Pair Square Hole Rails, Window Door on Front, Solid Door on Rear, Gasket Top Panel, Bottom, Casters, Levelers, and 120 V Ice Cube AC Unit.   230 Volt AC unit available. Contact us for details. 

Catalog
Number
Rack
Units
Overall Dimensions
HxWxD  in. [mm]
AC Unit
Size
DC-40U2442-AC12000-D 40U 77.00″ x 34.34″ x 44.13″
[1955 x 872 x 1120]
12,000 BTU
120V
DC-40U2436-AC12000-D 40U 77.00″ x 34.34″ x 38.88″
[1955 x 872 x 988]
12,000 BTU
120V
       
Catalog
Number
Rack
Units
Overall Dimensions
HxWxD  in. [mm]
AC Unit
Size
DC-40U2442-AC8000-D 40U 77.00″ x 34.34″ x 44.13″
[1955 x 872 x 1120]
8,000 BTU
120V
DC-40U2436-AC8000-D 40U 77.00″ x 34.34″ x 38.88″
[1955 x 872 x 988]
8,000 BTU
120V
 
 
defenderhalf

Half Rack – Self-contained Cooling Server Cabinet Systems
Includes: Frame, 2 Pair Square Hole Rails, Window Door on Front, Solid Door on Rear, Gasket Top Panel, Bottom, Casters, Levelers, and 120 V Ice Cube AC Unit.   230 Volt AC unit available. Contact us for details. 

Catalog
Number
Rack
Units
Overall Dimensions
HxWxD  in. [mm]
AC Unit
Size
DC-28U2442-AC8000-D 28U 56.00″ x 34.34″ x 44.13″
[1422 x 872 x 1120]
8,000 BTU
120V
DC-28U2436-AC8000-D 28U 56.00″ x 34.34″ x 38.88″
[1422 x 872 x 988]
8,000 BTU
120V
       
Catalog
Number
Rack
Units
Overall Dimensions
HxWxD  in. [mm]
AC Unit
Size
DC-28U2442-AC6000-D 28U 56.00″ x 34.34″ x 44.13″
[1422 x 872 x 1120]
6,000 BTU
120V
DC-28U2436-AC6000-D 28U 56.00″ x 34.34″ x 38.88″
[1422 x 872 x 988]
6,000 BTU
120V
       
Catalog
Number
Rack
Units
Overall Dimensions
HxWxD  in. [mm]
AC Unit
Size
DC-28U2442-AC3000-D 28U 56.00″ x 30.44″ x 44.13″
[1422 x 770 x 1120]
3,000 BTU
120V
DC-28U2436-AC3000-D 28U 56.00″ x 30.34″ x 38.88″
[1422 x 770 x 988]
3,000 BTU
120V

Literature

Need custom server cabinets?

We offer design services and solutions to meet the needs of any product specification, from examining current product prints to completing new product development. You can count on our expert resources and engineering capabilities to support any stage of your project, from concept to production. For more information on our capabilities download our Capabilities Brochure.